What must be kept together
LiSOCl₂ is a primary lithium system. Its public instructions must reflect non-rechargeable operation and the actual cell or pack construction; rechargeable-battery language must not be reused.
- Mark non-rechargeable use and model-specific handling limits clearly.
- Record lithium content and transport classification from approved evidence.
- Review pulse-current designs and any hybrid-capacitor assembly as a distinct configuration.
Correct product identity
Identify primary-cell chemistry, format, rated voltage and intended equipment. Maintain separate records for bobbin, spiral and hybrid pack configurations where their construction or test scope differs.
Safety communication
State that the battery must not be recharged, short-circuited, opened or heated beyond its approved limits. Use the model-specific SDS for leakage, fire and incident response.
Transport evidence
Keep the current transport summary and shipping classification tied to the finished product and its lithium content. Packaging and carrier instructions should be controlled outside the public QR page as operational documents.
Traceability
Link individual cell lots, pack assembly events and document revisions to the public Pack ID. A substituted cell or added pulse component requires a fresh applicability review.
Evidence to review before release
Approved model specification, BOM and supplier material declarations; applicable safety and transport documents; label artwork; manufacturing and quality records; current document revisions. Applicability depends on the exact product and destination market.
Primary regulatory reference: Regulation (EU) 2023/1542. This page explains a workflow and does not certify a particular product.
Need a model-specific record?
See the LP103450H-1S2P sample or contact our team about documentation for your battery configuration.
View sample record →Email VTC POWER